## Summary

Satellite cleanrooms, autoclaves, and additive-manufacturing cells in Kent and Tukwila cannot tolerate unscheduled power drops; valley flood events threaten at-grade transformers, fuel deliveries, and utility access.

## Documented Corridor Facts & Continuity Record

- Specific PSE/Seattle City Light substation feeder maps for individual private space facilities are not in our data and must be verified per site.
- What is documented is that SR 167 closures (such as Dec 15, 2025) sever diesel fuel-truck resupply routes for valley-floor backup generators.
- Facilities running ISO Class 7/8 cleanrooms, vacuum chambers, or thermal-vac tests require 72-hour on-site fuel autonomy and elevated transfer switches.

## Valley Facility Utility Continuity Controls

| System | Flood / Corridor Failure Mode | Control | Verification |
| --- | --- | --- | --- |
| Diesel Generators | Fuel truck blocked by SR 167 closure | Maintain >=72h on-site fuel | Pre-storm top-off trigger |
| Pad-Mount Transformers | Standing water / vault intrusion | Sandbag perimeter + elevation check | KCC 21A.24 Elevation Cert |
| Autoclaves / Cleanrooms | Grid sag during atmospheric rivers | UPS + automatic transfer switch | Monthly load-bank test |

## Operational Exposure & Facility Playbook

- Set an automatic fuel-top-off trigger whenever Green River flow forecasts reach Phase 2 flood alert.
- Verify that generator exhaust, day-tank vents, and fuel fill ports sit above the documented 100-year flood elevation.
- Cross-reference WA CBPS / Seattle BEPS compliance (#1984) so backup-power retrofits align with building-energy reporting.

## Connected Valley Cities, Segments & Role Briefs

- [WA Space Cluster Hub (#1382)](https://bcesg.org/washington-space-cluster-census/)
- [Facilities / EHS Desk Brief](https://bcesg.org/wa-space-role-facilities-ehs-desk-brief/)
- [Facilities: Waste, PSCAA & Floodplain](https://bcesg.org/wa-space-role-facilities-waste-pscaa-floodplain/)
- [Kent WA Space Cluster Profile](https://bcesg.org/kent-wa-space-cluster-profile/)
- [Satellite Mfg Continuity Exposure](https://bcesg.org/wa-satellite-manufacturing-continuity-exposure/)

## Primary Sources & Agency References

- [King County Flood Services](https://kingcounty.gov/en/dept/dnrp/nature-recreation/environment-ecology-conservation/flood-services)
- [WA EMD Regional Plans (Recovery Annex)](https://mil.wa.gov/plans)